The solution for
• Data servers
• Telecommunications
• Service sector
Advantages
A COMPLETE, COST-EFFECTIVE SOLUTION
• Online double conversion mode with an output power factor of 0.9 providing 12% more active power compare to UPS with a power factor of 0.8.
• Dual input mains allows you to manage independent power sources.
• Increased system availability placing two UPS in parallel for 1+1 redundancy
• Internal manual bypass for easy maintenance without power interruption.
• Internal batteries providing more than 1 hour runtime (MASTERYS BC 15-80 kVA).
• Multilanguage display.
TAILORED TO YOUR ENVIRONMENT
• Saves space with a reduced footprint and optimized cabinet size.
• Low noise level.
• Flexible battery solutions
• Compact, lightweight and easy to install
• Extended battery life and performance with exclusive EBS battery charging management for increased battery life.
STANDARD ELECTRICAL FEATURES
• Dual input mains.
• Internal maintanance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery management.
ELECTRICAL OPTIONS
• External battery cabinet.
• External temperature sensor.
• Additional battery chargers.
• Galvanic isolation transformer.
• Parallel kit.
• ACS synchronization system.
STANDARD COMMUNICATION FEATURES
• MODBUS/JBUS RTU.
• 2 slots for communication options.
COMMUNICATION OPTIONS
• Dry-contact interface.
• Remote mimic panel.
• MODBUS TCP.
• PROFIBUS
• NET VISION: professional WEB/SNM interface for UPS monitoring and shutdown management of several operating systems.
REMOTE MONITORING SERVICE
• LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24 / 7.
UPS and internal batteries
|
|
|
Cabinet type S height 800 mm
Cabinet type M height 1000 mm
Cabinet type T height 1400 mm |
Technical data
Sn [kVA] |
15 |
20 |
30 |
40 |
60 |
80 |
100 |
120 |
Pn [kW] |
13.5 |
18 |
27 |
36 |
54 |
72 |
90 |
108 |
Input / output 3/1 |
• |
• |
- |
- |
- |
- |
- |
- |
Input / output 3/3 |
• |
• |
• |
• |
• |
• |
• |
• |
Parallel configuration |
1+1 (1) |
Input |
Rated voltage |
400 V (3ph + N) |
Voltage tolerances |
240 V to 480 V(2) |
Rated frequency |
50/60 Hz ± 10% |
Power factor / THDI |
0.99 / < 3% |
Output |
Rated voltage |
1ph + N: 230 V (can be configured 220/240 V)
3ph + N: 400 V (can be configured 380/415 V) |
Voltage tolerance |
static load ±1% dynamic load in accordance with VFI-SS-111 |
Rated frequency |
50/60 Hz |
Frequency tolerance |
± 2% (configurable from 1% to 8%) |
Overload |
125% for 10 minutes, 150% for 1 minute |
Crest factor |
3:1 |
Bypass |
Rated voltage |
rated output voltage |
Voltage tolerance |
± 15% (configurable with from 10% to 20%) |
Rated frequency |
50/60 Hz |
Frequency tolerance |
± 2% (configurable for Genset compatibility) |
Efficiency |
Online mode @ 100 % of load |
up to 94% |
Environment |
Operating ambient temperature |
from 0 °C up to 40(2) °C (from 15 °C to 25 °C for maximum battery life) |
Relative humidity |
0% – 95% without condensation |
Maximum altitude |
1000 m without derating (max. 3000 m) |
Acoustic level at 1 m
(ISO 3746) |
< 52 dBA |
< 55 dBA |
< 62 dBA |
< 65 dBA |
UPS cabinet |
Dimensions W x D x H |
444 x 795 x 800 / 1000 / 1400 mm |
444 x 795 x 1400 mm |
700 x 800 x 1930 mm |
Weight |
105 kg(3) |
110 kg(3) |
135 kg(3) |
152 kg(3) |
180 kg(3) |
200 kg(3) |
410 kg |
430 kg |
Degree of protection |
IP20 |
Colours |
RAL 7012 |
RAL 7012, silver grey frontal door |
Standards |
Safety |
EN 62040-1 (TÜV SÜD certified), EN 60950-1 |
Performance |
EN62040-3 (VFI-SS-111) |
EMC |
EN62040-2 |
Product declaration |
CE |
|
(1) The standard model is prepared for a 1+1 redundant system. Upon request, it is possible to have connected up to 6 modules in a parallel system.
(2) Conditions apply.
(3) Without batteries.