Advantages

A COMPLETE, COST-EFFECTIVE SOLUTION

• Online double conversion mode with an output power factor of 0.9 providing 12% more active power compare to UPS with a power factor of 0.8.
• Dual input mains allows you to manage independent power sources.
• Increased system availability placing two UPS in parallel for 1+1 redundancy
• Internal manual bypass for easy maintenance without power interruption.

• Internal batteries providing more than 1 hour runtime (MASTERYS BC 15-80 kVA).
• Multilanguage display.

TAILORED TO YOUR ENVIRONMENT

• Saves space with a reduced footprint and optimized cabinet size.
• Low noise level.
• Flexible battery solutions
• Compact, lightweight and easy to install
• Extended battery life and performance with exclusive EBS battery charging management for increased battery life.

STANDARD ELECTRICAL FEATURES

• Dual input mains.
• Internal maintanance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery management.

ELECTRICAL OPTIONS

• External battery cabinet.
• External temperature sensor.
• Additional battery chargers.
• Galvanic isolation transformer.
• Parallel kit.
• ACS synchronization system.

STANDARD COMMUNICATION FEATURES

• MODBUS/JBUS RTU.
• 2 slots for communication options.

COMMUNICATION OPTIONS

• Dry-contact interface.
• Remote mimic panel.
• MODBUS TCP.
• PROFIBUS
• NET VISION: professional WEB/SNM interface for UPS monitoring and shutdown management of several operating systems.

REMOTE MONITORING SERVICE

• LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24 / 7.

UPS and internal batteries

 

Cabinet type S height 800 mm
Cabinet type M height 1000 mm
Cabinet type T height 1400 mm

 

Technical data

 

Sn [kVA] 15 20 30 40 60 80 100 120
Pn [kW] 13.5 18 27 36 54 72 90 108
Input / output 3/1 - - - - - -
Input / output 3/3
Parallel configuration 1+1 (1)
Input
Rated voltage 400 V (3ph + N)
Voltage tolerances 240 V to 480 V(2)
Rated frequency 50/60 Hz ± 10%
Power factor / THDI 0.99 / < 3%
Output
Rated voltage 1ph + N: 230 V (can be configured 220/240 V)
3ph + N: 400 V (can be configured 380/415 V)
Voltage tolerance  static load ±1% dynamic load in accordance with VFI-SS-111
Rated frequency 50/60 Hz
Frequency tolerance ± 2% (configurable from 1% to 8%)
Overload 125% for 10 minutes, 150% for 1 minute
Crest factor 3:1
Bypass
Rated voltage rated output voltage
Voltage tolerance ± 15% (configurable with from 10% to 20%)
Rated frequency 50/60 Hz
Frequency tolerance ± 2% (configurable for Genset compatibility)
Efficiency
Online mode @ 100 % of load up to 94%
Environment
Operating ambient temperature from 0 °C up to 40(2) °C (from 15 °C to 25 °C for maximum battery life)
Relative humidity 0% – 95% without condensation
Maximum altitude 1000 m without derating (max. 3000 m)
Acoustic level at 1 m
(ISO 3746)
< 52 dBA < 55 dBA < 62 dBA < 65 dBA
UPS cabinet
Dimensions W x D x H 444 x 795 x 800  / 1000 / 1400 mm 444 x 795 x 1400 mm 700 x 800 x 1930 mm
Weight 105 kg(3) 110 kg(3) 135 kg(3) 152 kg(3) 180 kg(3) 200 kg(3) 410 kg 430 kg
Degree of protection IP20
Colours RAL 7012 RAL 7012, silver grey frontal door
Standards
Safety EN 62040-1 (TÜV SÜD certified), EN 60950-1
Performance EN62040-3 (VFI-SS-111)
EMC EN62040-2
Product declaration CE

(1) The standard model is prepared for a 1+1 redundant system. Upon request, it is possible to have connected up to 6 modules in a parallel system.
(2) Conditions apply.
(3) Without batteries.